The series of X20 compact CPUs features three integrated I/O modules. The device is equipped with 30 different digital inputs/outputs and two analog inputs. One analog input can be used for PT1000 resistance temperature measurement.
The X20CP1381 is equipped with an Intel x86 200 MHz compatible processor, 128 MB RAM and 1 GB built-in flash drive. The FRAM for saving remanent variables has 16 kB available. A fanless design without batteries guarantees maintenance-free operation.
The CPU is also equipped with one Ethernet, two USB and one RS232 interface. POWERLINK and CAN bus are also available as integrated interfaces. If additional fieldbus connections are needed, the CPU can be upgraded with an interface module from the standard X20 product range.
Interfaces | 1x RS232, 1x Ethernet, 1x POWERLINK, 2x USB, 1x X2X Link, 1x CAN bus |
System module | CPU |
B&R ID code | 0xE35C |
Cooling | Fanless |
Status indicators | CPU function, Ethernet, POWERLINK, RS232, CAN bus, CAN bus terminating resistor, CPU power supply, I/O power supply, I/O function per channel |
Diagnostics | |
Outputs | Digital outputs: Yes, using LED status indicator and software (output error status) |
CPU function | Yes, using LED status indicator |
CAN bus data transfer | Yes, using LED status indicator |
RS232 data transfer | Yes, using LED status indicator |
Inputs | Analog inputs: Yes, using LED status indicator and software |
Ethernet | Yes, using LED status indicator |
I/O power supply | Yes, using LED status indicator |
POWERLINK | Yes, using LED status indicator |
Supply voltage monitoring | Yes, using LED status indicator |
Temperature | Yes, using software register |
Terminating resistor | Yes, using LED status indicator |
Support | |
Controller redundancy possible | No |
ACOPOS support | Yes |
reACTION-capable I/O channels | No |
Visual Components support | Yes |
Power consumption without interface module and USB | 4.8 W |
Power consumption for X2X Link power supply | 0.8 W |
Power consumption | |
Internal I/O | 0.8 W |
Additional power dissipation caused by actuators (resistive) [W] | - |
Type of signal lines | Shielded cables must be used for all high-speed digital inputs/outputs, cable length: Max. 20 m |
Certifications | |
CE | Yes |
ATEX |
Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X |
UL |
cULus E115267 Industrial control equipment |
HazLoc |
cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
DNV GL |
Temperature: B (0 - 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck) |
LR | ENV1 |
KR | Yes |
ABS | Yes |
EAC | Yes |